The NNC67F miniature electromagnetic relay can be applied to industrial control system and automatic control system, etc.
CCC:2011010303478444
CQC:CQC14002106906
CE:5398080516
TUV:R50301238
UL:E235027
Contact form | 1Z,1H,1D | ||
Contact load | 30A | 40A | |
Maximum switching voltage | 277VAC 30A 30VDC 30A | 277VAC 40A 30VDC 40A | |
Contact material | Silver alloy |
Rated voltage V | DC6V | DC12V | DC24V | DC48V | |
Rated current (±10%) mA | 155 | 78 | 39 | 19.3 | |
Coil resistance (±10%) Ω | 39 | 155 | 620 | 2487 | |
Rated power consumption W | 0.93W | ||||
Pull-in voltage (Maximum) V | Below75% | ||||
Drop-out voltage(Minimum) V | Above10% | ||||
Allowable voltage(Maximum) V | Rated voltage×110% | ||||
Rated voltage V | AC12V | AC24V | AC110V | AC220V | |
Rated current (±10%) mA | 100 | 50 | 11 | 6 | |
Coil resistance (±10%) Ω | 42 | 168 | 3500 | 14000 | |
Rated power consumption W | 1.2VA | ||||
Pull-in voltage (Maximum) V | Below 80% | ||||
Drop-out voltage(Minimum) V | Above 30% | ||||
Allowable voltage(Maximum) V | Rated voltage×110% |
Coil voltage | DC:3 -110V AC:6-240V | |
Pull-in time | ≤15ms | |
Drop-out time | ≤10ms | |
Withstand voltage | Between the homopolar contacts | 1800VAC/1min(Leakage current 1mA) |
Between the heteropolar contacts | / | |
Between contacts and coil | 2500,4500 VAC/1min(Leakage current 1mA) | |
Dimension | 32.4× 27.4 × 28.6mm | |
Weight | About 30 g |
① Front view; ② Side view; ③ Installation size; ④ Wiring diagram
Index
relay switch, electric switch, electrical device
Clion Electric Co.,Ltd.
Add.: No.319, Wei 18 Rd.,Yueqing Economic Development Zone,Yueqing City, Zhejiang Province, 325600
Contact Person: Tony Chen
Tel.: +86-577-57156992
Fax: +86-577-57572255
E-mail: clionrelay@hotmail.com