The NNC71F-2Z electromagnetic power relay (JQX-62F-2Z) can be applied to household appliances, mechanical control, industrial equipment, industrial control system, automatic control system, agricultural equipment and power transmission and distribution, etc.
CCC:2011010303471251
CE:5401090516
UL:E235027
Contact form | 2Z,2H,2D |
Contact load | 80A |
Maximum switching voltage | 240VAC 80A 28VDC 80A |
Contact material | Silver alloy |
Rated voltage V | DC12V | DC24V | DC110V | DC220V |
Rated current (±10%) mA | 300 | 150 | 32.7 | 16.4 |
Coil resistance(±10%) Ω | 40 | 160 | 3364 | 13414 |
Rated power consumption W | 3.6W | |||
Pull-in voltage (Maximum) V | Below 75% | |||
Drop-out voltage(Minimum)V | Above 10% | |||
Allowable voltage(Maximum) V | Rated voltage×110% | |||
Rated voltage V | AC12V | AC24V | AC110V | AC220V |
Rated current (±10%) mA | 875 | 437.5 | 95.4 | 47.7 |
Coil resistance(±10%) Ω | 4.7 | 19 | 403.5 | 1614 |
Rated power consumption W | 10.5VA | |||
Pull-in voltage (Maximum) V | Below 80% | |||
Drop-out voltage(Minimum)V | Above 30% | |||
Allowable voltage(Maximum) V | Rated voltage×110% |
Coil voltage | DC:6 - 220V AC:6-380V | |
Pull-in time | ≤25ms | |
Drop-out time | ≤25ms | |
withstand voltage | Between the homopolarcontacts | 1500VAC/1min(Leakage current 1mA) |
Between the heteropolarcontacts | / | |
Between contacts and coil | 2500VAC/1min(Leakage current 1mA) | |
Insulation resistance | ≥200MΩ(500VDC) | |
Size | 85 ×68 ×65mm | |
Weight | About 210g |
① Front view; ② Underside view; ③ Wire diagram
Index
relay switch, electric switch, electrical device
Clion Electric Co.,Ltd.
Add.: No.319, Wei 18 Rd.,Yueqing Economic Development Zone,Yueqing City, Zhejiang Province, 325600
Contact Person: Tony Chen
Tel.: +86-577-57156992
Fax: +86-577-57572255
E-mail: clionrelay@hotmail.com